Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti BDNF antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of BDNF in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti OC/BGP antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of OC/BGP in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti IL-35 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of IL-35 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with Cortisol. Cortisol in the sample or standard competes with a fixed amount of biotin-labeled Cortisol for sites on a pre-coated antibody specific to Cortisol. Read the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of Cortisol in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti BALP antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of BALP in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti IL-4 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of IL-4 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti Bax antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of Bax in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with HCY. HCY in the sample or standard competes with a fixed amount of biotin-labeled HCY for sites on a pre-coated antibody specific to HCY. Read the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of HCY in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with VB 12. VB 12 in the sample or standard competes with a fixed amount of biotin-labeled VB 12 for sites on a pre-coated antibody specific to VB 12. Read the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of VB 12 in the sample. The concentration of the target substance is inversely proportional to the OD450 value.