Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti CXCL15 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of CXCL15 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti IL-6 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of IL-6 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with S1P. S1P in the sample or standard competes with a fixed amount of biotin-labeled S1P for sites on a pre-coated antibody specific to S1P. Read the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of S1P in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti pro-BDNF antibody. Add standard and properly diluted sample into relevant well respectively. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of pro-BDNF in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti KL antibody. Add standard and properly diluted sample into relevant well respectively. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of KL in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti Hspa5 antibody. Add standard and properly diluted sample into relevant well respectively. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of Hspa5 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Competitive-ELISA detection method and takes 2h assay time. The microplate provided in this kit has been precoated with COR. COR in the sample or standard competes with a fixed amount of biotin-labeled COR for sites on a pre-coated antibody specific to COR. Read the O.D. absorbance at 450nm in a microplate reader. Compare OD450 value of sample with the standard curve through curve fitting software to determine the concentration of COR in the sample. The concentration of the target substance is inversely proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti TIMP-1 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of TIMP-1 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Manufacturer: Finetest
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti COL2 antibody. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of COL2 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.