Mould Incubator
Mould Incubator Specifications:
Model | UICB-80MP | UICB-150MP | UICB-250MP | UICB-350MP | UICB-460MP | |
---|---|---|---|---|---|---|
Capacity(L) | 80 | 150 | 250 | 350 | 460 | |
Circulation Mode | Forced convection | |||||
Size(WxDxH)(mm) | Internal | 400x400x500 | 400x500x750 | 500x550x910 | 600x600x1000 | 650x650x1100 |
External | 625x550x1065 | 600x660x1360 | 720x710x157 | 800x760x1610 | 850x810x1715 | |
Temperature | Range (℃) | 0 ~ 65 | ||||
Fluctuation (℃) | ≤1℃ | |||||
Resolution (℃) | 0.1 | |||||
Uniformity (℃) | ±1 | |||||
Sensor | PT100 | |||||
Humidity | Rang | - | ||||
Stability | - | |||||
Method | - | |||||
Sensor | - | |||||
Controller | PID | |||||
Display | Large high definition LCD | |||||
Timer | 0~9999/99*5Segments (with timing wait function) | |||||
Material | Internal | Mirror stainless steel | ||||
External | Cold rolled steel electrostaticspraying exterior | |||||
Lighting System | Ultraviolet germicidal lamp | |||||
Test Hole | Φ43mm | |||||
External Socket | Universal socket(one) | |||||
Refrigerant | R134a (CFC free) | |||||
Defrosting Mode | Automatic | |||||
Safety Device | Over temperature, over humidity, water shortage alarm | |||||
Electricity | Voltage /Frequency | AC 220/110V, 50/60Hz | ||||
Consumption (W) | 600 | 800 | 1000 | 1200 | 1400 | |
G.W. (kg) | 61 | 88 | 112 | 139 | 168 | |
Shipping Size (WxDxH)(mm) | 690x620x1150 | 770x735x1520 | 820x800x1660 | 870x860x1800 | 990x1040x1970 | |
Standard | USB port for storing and exporting data | |||||
Optional | 485 interface, printer and spare shelf |
Mould Incubator Features:
- 304 stainless steel inner liner, the four corners are semi-circular, the shelf support can be freely loaded and unloaded, easy to clean the working room.
- The unique geometric cavity clean design ensures perfect active sample protection.
- The box shell is treated by electrostatic spraying process, beautiful and generous, anti-corrosion and durable.
- Large touch screen, multiple groups of data on one screen display, 99*5 segment program control, with temperature curve, data storage function
- Famous brand compressor and circulating fan, high efficiency, low consumption and energy saving.
- Set a limited temperature alarm system, over temperature self-limit, automatic power off and timing functions to ensure the safety of the experiment.
- Double-layer door structure, the inner door is made of high-quality tempered glass for sample observation, and the outer door is made of magnetic rubber strip for easy opening and closing and good sealing.
- Good thermal insulation design to ensure good sealing and prevent temperature loss.
- The work room is illuminated for easy observation.