Automatic Vertical Autoclave 50/80/100/120/150L
Automatic Vertical Autoclave Specifications:
Model | UST-V50A | UST-V80A | UST-V100A | UST-V120A | UST-V150A |
---|---|---|---|---|---|
Capacity | 50L | 80L | 100L | 120L | 150L |
External Size (WxDxH)(mm) | 476x616x990 | 546x688x1030 | 566x708x1295 | 620x760x1190 | 680x820x1180 |
Chamber Size (ØxH)(mm) | Ø316x667 | Ø386x695 | Ø400x800 | Ø450x760 | Ø500x780 |
Chamber Material | SUS304 | ||||
Sterilization Temperature | 105~136 ℃ | ||||
Designed Temperature | 150℃ | ||||
Max.Working Temperature | 136 ℃ | ||||
Dissolution Temperature | 40~100℃ | ||||
Warming Temperature | 40~60℃ | ||||
Temp.Accuracy | 0.1℃ | ||||
Designed Pressure | 0.3Mpa | ||||
Max.Sterilization Pressure | 0.23Mpa | ||||
Sterilization Time Range | 0~99min | ||||
Display | LCD touch screen | ||||
Drying Function | YES | ||||
Drying Time | 15min | ||||
Sterilization Program | ●Dressings/Fabric program ●Tools program ●Rubber program ●Culture medium sterilization warming program ●Culture medium dissolution warming program ●Liquids in closed containers (glass bottle, plastic bottle and bag) program ●Waste program | ||||
Water Injection Method | Built-in water tank | ||||
Power Consumption | 3KW | 4.5KW | 5.4KW | 5.4KW | 9.3KW |
Power Supply | 220V 50Hz | 220V 50Hz | 220V 50Hz | 380V 50Hz | 380V 50Hz |
Standard SS Basket | 2pcs | 2pcs | 2pcs | 2pcs | 2pcs |
Optional Accessories | Printer, USB port | ||||
Net Weight | 68kg | 92kg | 100kg | 175kg | 195kg |
Gross Weight | 103kg | 127kg | 140kg | 215kg | 235kg |
Shipping Size (WxDxH)(mm) | 730x820x1250 | 800x880x1300 | 800x880x1480 | 950x1050x1280 | 950x1050x1440 |
Automatic Vertical Autoclave Features:
- Overheat protection: Automatically cutting off heating with audible and visual indication when the autoclave is overheated.
- Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
- Interlock safety: Preventing from starting a cycle if door is not properly closed or from door opening if there is pressure inside chamber.
- Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
- Automatic operation of sterilization with PID microprocessor control and LCD display.
- Positive pulsing function removes the air efficiently.
- Liquid program with automatic pressure control prevents boil over of liquids and explosions of bottles or bags.
- With Power-off memory function.
- Internal water tank with steam-water internal circulation.
- Standard printer, real-time record sterilization process,error and alarm information.