Vertical Pulse Vacuum Autoclave 50/80/100/120/150L
Vertical Pulse Vacuum Autoclave Specifications:
Model | UST-V50PV | UST-V80PV | UST-V100PV | UST-V120PV | UST-V150PV |
Capacity | 50L | 80L | 100L | 120L | 150L |
External Size (WxDxH)(mm) | 580x636x990 | 636x710x1030 | 630x710x1295 | 700x780x1190 | 780x850x1180 |
Chamber Size (ØxH)(mm) | Ø316x667 | Ø386x695 | Ø386x860 | Ø450x760 | Ø500x780 |
Chamber Material | SUS304 | ||||
Sterilization Temperature | 105~136 ℃ | ||||
Designed Temperature | 150℃ | ||||
Max. Working Temperature | 136 ℃ | ||||
Dissolution Temperature | 40~100℃ | ||||
Warming Temperature | 40~60℃ | ||||
Temp.Accuracy | 0.1℃ | ||||
Temp. Uniformity | ≤±0.5℃ | ||||
Designed Pressure | 0.3Mpa | ||||
Max.Sterilization Pressure | 0.23Mpa | ||||
Ultimate Vacuum | -0.096MPa | ||||
Pressure Resoluiton | 0.1KPa | ||||
Sterilization Time Range | 0~99min | ||||
Temp. Controller | PID control by microprocessor | ||||
Display | LCD touch screen | ||||
Drying Function | YES | ||||
Drying Time | 15min | ||||
Sterilization Program | ●Medical instrument program ●Luminal instruments ●Dressings/Fabric program ●Rubber program ●Liquid program ●BD Test program ●Vacuum Test progrm Sterilization of medical dressing, medical Instruments, Instruments with cavity, Rubber, liquids plus 4 user-customized programs BD Test and vacuum test. | ||||
Water Injection Method | Built-in water tank | ||||
Power Consumption | 3KW | 4.5KW | 5.4KW | 7.2KW | 9.3KW |
Power Supply | 220V 50Hz | 220V 50Hz | 220V 50Hz | 380V 50Hz | 380V 50Hz |
Standard SS Basket | 2pcs | 2pcs | 2pcs | 2pcs | 2pcs |
Net Weight | 85kg | 95kg | 112kg | 180kg | 210kg |
Gross Weight | 122kg | 130kg | 152kg | 220kg | 250kg |
Shipping Size (WxDxH)(mm) | 840x770x1170 | 880x910x1300 | 880x910x1550 | 1030x1050x1300 | 1030x1050x1450 |
Vertical Pulse Vacuum Autoclave Features:
- Overheat protection: Automatically cutting off heating with audible and visual indication when the autoclave is overheated.
- Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
- Interlock safety: Preventing from starting a cycle if door is not properly closed or from door opening if there is pressure inside chamber.
- Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
- Automatic operation from sterilization to drying (Pre-vacuum sequence, heating, sterilization, steam discharge and post-vacuum drying) can be easily set and monitored by the LCD touch screen
- Built-in vacuum pump provides 3-time pulsed vacuum process,extracting the air out of the medical dressing and the Class A hollow medical instrument efficiently.
- Built-in steam generator prevents the media from contamination.
- Post-vacuum drying function offers efficient drying results.
- Positive pulsing function removes the air efficiently.
- With 0.22µm air filter, blocks all microorganisms from exiting the chamber during the air removal phase.
- Standard built-in printer, real-time record sterilization process, error and alarm information.