Cassette Sterilizer, Three-layer
Cassette Sterilizer Specifications:
Model | UST-2000TC | UST-5000TC | UST-6000TC |
---|---|---|---|
External Size (WxDxH)(mm) | 280x600×660 | ||
Cassette External Size (WxDxH)(mm) | 196x390×40 | 196x480×80 | 196x×196×80 |
Cassette Internal Size (WxDxH)(mm) | 180x280×38 | 180x380×78 | 180x480×78 |
Cassette Capacity | 1.8Lx3 | 5.2Lx3 | 6.0Lx3 |
Rated Working Temperature | 138℃ | ||
Rated Working Pressure | 242kPa | ||
Working Temperature Range | 115 ℃~135 ℃ | ||
Water Tank Capacity | 2.5L | ||
Power Supply | AC 220V ± 22V; 50Hz ± 1Hz; | ||
Working Medium | Water vapor | ||
Water Source Supply | Ultrapure water, deionized water, laboratory water, distilled water, purified water | ||
Working Mode | Intermittent operation (≤6 cycles/hour) | ||
Atmospheric Pressure Range | 70.0kPa~106.0kPa | ||
Environmental Temperature Range | +5 ℃ to+40 ℃ | ||
Working Relative Humidity | ≤ 85% | ||
External Size (WxDxH)(mm) | 280x600×660 | ||
Package Size (WxDxH)(mm) | 460x710x810 | ||
Net Weight(kg) | 60 | 84 | 86 |
Gross Weight | 80 | 104 | 106 |
Cassette Sterilizer Features:
- The sterilization effect is reliable and rapid, positive pressure pulsating exhaust sterilization, and the entire sterilization process only takes 7-10 minutes. It is suitable for multi department instrument continuous surgery and emergency sterilization.
- 7-inch touch interface, graphical operation. The system operation status is displayed on the screen, and the sterilization program can be safely interrupted at any time.
- Compact design, saving space. Each layer is independently controlled.
- Multi level permission management ensures the authenticity and effectiveness of sterilization data. Network communication interface, which can be connected to the traceability system.
- Equipped with a built-in self-priming circulating water tank and automatic water inlet function, the program operation is not affected by the volume of the water tank, and it is equipped with a low water level detector to prevent the evaporator from dry burning.
- Built in thermal printer, real-time recording of sterilization process parameters, with the function of recording and storing the last 60 running processes.
- Equipped with USB interface for data storage.
- Self inspection system. Once a problem occurs during operation, the system automatically terminates operation and displays a fault code on the screen.
- Customize the settings program to meet the sterilization requirements of various large and special instruments.