Benchtop Pulse Vacuum Autoclave, Class B
Benchtop Pulse Vacuum Autoclave Specifications:
Model | UST-B60PV | UST-B80PV |
---|---|---|
Capacity | 60L | 80L |
Chamber Size(mm) | φ386x520 | φ386x692 |
Designed Pressure | -0.1/0.3Mpa | |
Sterilization Temperature | 150℃ | |
Wokring Temperature | 121℃/134℃ | |
Water Tank Capacity(L) | 14 | |
Chamber Material | SUS304 | |
Noise | ≤65dB | |
Consumption | 5.8kW | 6.2kW |
Power Supply | 220V/110V, 50/60HZ | |
External Size(WxDxH)(mm) | 940x805x700 | 1140x805x700 |
Package Size(WxDxH)(mm) | 1130x960x940 | 1330x960x940 |
N.W./G.W. (kg) | 175/215 | 185/230 |
Benchtop Pulse Vacuum Autoclave Features:
- Display:
- The LCD touch screen can display temperature, pressure, time, operating status, fault alarm, equipment operation curve and other information in real time, making the sterilization information more intuitive and clear, and convenient for users to observe the operating status of the equipment
- Process control:
- The whole process of preheating, replacement, heating, sterilization, exhaust and vacuum drying is automatically operated; it uses steam as the medium, adopts an efficient vacuum pumping system, and repeatedly pumps vacuum to achieve the effect of sterilization and drying.
- Multi-point Temperature Control Technology:
- Non-sealed liquid programs use mobile temperature sensors to measure temperature, which can detect the internal temperature of the liquid in real time, making the internal temperature of the liquid more intuitive and clear.
- Insulation Function:
- The insulation function can be set as needed to achieve liquid culture medium sterilization, culture medium dissolution-insulation function
- Safety Function:
- With over-temperature automatic protection device, anti-dry burning protection device, over-pressure automatic release device, over-current protection device, electronic circuit safety device
- Self-calibration Function:
- It has a complete background self-calibration system to realize the calibration of system parameters such as pressure and temperature. Without disassembling the instrument, the authorized tool can be used for on-site adjustment.
- Independently Installed Pressure Sensors:
- An independent pressure transmitter is installed in each of the inner chamber and evaporator to ensure that the equipment pressure is within the safe control range
- Sterilization Program:
- Encapsulation Program, Rubber Program, Dressing Program, Liquid Program, Liquid customization, Solid customization, as well as B & D testing, vacuum testing Program, Medium Sterilization & Dissolution.
- Water Injection and Drainage Method: automatic water injection, automatic drainage
- Pressure Gauge: Range: -0.1~0.5MPa
- Accuracy level: 1.6
- Filter: Manually removable filter, easy to clean, more user-friendly